Advanced:Advanced Netagent UPS Setting
In order to ensure the secure management of UPS, Netility provides two
protecting function:
Netility Password
After password setting here, there is no way to give any command to Netagent
by Netility software without user’s password. (NB. If lose this password,
Netagent UPS will never be able to complete any upgrade process.)
Management Protocol
Netagent UPS provides HTTP(WEB) and Telnet to reference any related
parameter setting for the manager. Concerning with security, the manager
could build use openly or any advance port setting upon the above two
methods. Followings are the description:
1. At advanced setting, two functions were set as activated by using port
number 80 and 23.
2. Untick means not using the function.
3. When set to the other port value, full IP Address must be entered in order to
login to the website or Telnet.
For example,
Set 81 as HTTP port number, then http://192.168.0.177:81 must be typed
at the web address to proceed to Netagent UPS’s website.
Set 24 as Telnet port number, then "192.168.0.177 24" must be typed at
Telnet to proceed to the Telnet screen of NetAgent UPS.
Fig.13 Netility : Advanced setting of Netagent UPS
Download Firmware
NetAgent offer convenient firmware upgrade function. When you are going to
upgrade firmware, click
Download Firmware from NetAgent Setup menu, click
“Browser” select new firmware file (*.bin) and press “Start”. Thus, Net Agent’s Red
LED and Yellow LED flashing alternative means the firmware is upgrading. After
upgrade completed, Net Agent will auto reboot.
(Please connect to the
http://www.megatec.com.tw/CustomerService/Download/CSDownload.htm)
for the latest firmware)